Liquid Chromatography Lab

by

Introduction
We are using liquid chromatography to separate the colored substances in grape-flavored drinks. We separate the component dyes, and then we separate the flavorings and citric acids.
BackgroundChromatography is a process that is used to separate a substance into its component parts. The separation occurs between the stationary and moving phase of the lab. The moving phase consists of a fluid and the stationary phase consists of a solid. The mixture we are trying to split up is integrated into the mobile phase.
When the mobile phase interacts with the solid phase, the components of the mixture are attracted to the solid phase in varying degrees. Components with higher levels of attraction for the mobile phase result in a faster speed of transport throughout the solid phase. Components with higher levels of attraction for the solid phase result in a slower speed of transport throughout the solid phase. These differing levels of attraction end up in the separation of the mixture into component bands, which exit the system as distinct liquids.
Liquid chromatography labs are composed of six main parts:
a. A separation column filled with a fine-grain solid.
b. A solvent (mobile phase) that moves through the separation column.
c. An injection system to transport the solvent to the separation column.
d. A pump to force the solvent through the separation column.
e. A detector to determine when the components exit the separation column.
f. A recorder
Although in most chromatography labs the solid phase is polar and the mobile phase is nonpolar, we are using Reverse Phase Liquid Chromatography, where the mobile phase is polar and the solid phase is nonpolar.
Also read: Fluorenol Polarity
When the mobile phase interacts with the solid phase, the polar parts of the mobile phase are attracted to each other, so they wash through the column quickly. The less polar components of the mobile phase are attracted to the nonpolar solid in the column, so they wash through the column slowly. This results in a separation of the components, whose degree is measured as the resolution.
Pre-Lab QuestionsWhat is the process of chromatography used for?
In the chromatography, components of a mixture distribute themselves between the stationary phase and the mobile phase. Explain how the components can be separated from these two phases.
In the liquid chromatography column used in this experiment, the solid has a C18 hydrocarbon bonded to it. Would a C18 hydrocarbon be polar or nonpolar? Explain.
Below are the typical data for this experiment. 1 mL of a Kool-Aid solution was loaded on a Sep-Pak C18 Column. The red and blue dyes were eluted from the column with a constant flow of 18% isopropyl alcohol. The eluted solution was collected in a 10 mL graduated cylinder. The volumes of eluant were recorded at the beginning and end of each color band.Information
The first step in calculating the selectivity and resolution of the system is determining the volumes of eluant corresponding to the bandwidths and band centers for each eluted dye.
a. Bandwidth W is the volume in mL of eluant containing each dye as it emerges from the column. Calculate the bandwidth W for each dye for each of the three runs and then determine the average bandwidth W average for each dye.
b. The Center of the band, called Average Retention Volume V Rave corresponds to the center of each band.
V Rave = V start + (½) W Rave
Calculate the average retention volume, V Rave, for the red and blue dyes.
c. For each dye, a capacity factor k’ can be calculated. This term is a relative measure of the attraction of the dye for the stationary phase as compared to its attraction for the mobile phase. The equation fo capacity factor is:
k’ = (V Rave – V M)/V M
here, V Rave is the average retention volume for each dye, and V M is the mobile phase or eluant volume in the cartridge. V M can be estimated to be one half the cartridge volume, with the stationary phase occupying the other half. For the Sep-Pak cartridges, this V M value is 0. 49 mL. Calculate k’ for each dye.
d. A selectivity or separation factor, alpha, can now be calculated. This is the ratio of the k’ values for each dye, with the larger value in the numerator. For good separation, a mobile phase is usually chosen which gives an alpha value between 2 and 10. Calculate alpha for this separation: alpha = (k’ Blue)/(k’ Red)
e. The resolution R, a measure of how well the two dyes are separated by the column and eluant, is determined by the equation R = 2(V Rave Blue – V Rave Red)/(W Blue + W Red)
where the numerator is the volume between the band centers and the denominator represents the average bandwidth. The greater the selectivity, the larger the numerator, and therefore the greater the resolution. The resolution can also increase as the efficiency of the column increases since this results in lower average bandwidth. Calculate R for this separation.
MaterialsIsopropyl Alcohol, 70% 50 mL
Isopropyl Alcohol, 28%, 10 mL
Isopropyl Alcohol, 18% 50 mL
Isopropyl Alcohol, 5% 10 mL
Graduated Cylinder, 10mL
Graduated Cylinder, 25 mL
Distilled Water, 300 mL
Grape Koolaid Solution, 20 mL
Sep-Pak C18
Cartridge 10 mL
Syringe w/ male Luer tip Beaker, 100 mL,
3 Beaker, 50 mL.Safety Precautions
Isopropyl alcohol is inflammable and a fire hazard. Do not conduct this laboratory in the presence of flames. This alcohol is slightly toxic by ingestion and inhalation. Chemical-resistant goggles, gloves, and aprons are required. Wash and rinse hands thoroughly with soap and water after conducting the lab.
Procedure
Part 1: Isocratic Separation (Constant rate of flow and solvent concentration) Pretreatment of the Sep-Pak C18 CartridgeCut off the exit tube/shorter end of the cartridge at the point where it meets the body of the cartridge.
Load the syringe with 10mL of 70% isopropyl alcohol.
Connect the tip of the syringe to the long end of the Sep-Pak cartridge.
Pump the isopropyl alcohol through the syringe cartridge at a rate of 5-10 mL/minute.
Collect the alcohol in a 10 mL graduated cylinder to monitor the flow rate.
Repeat previous steps with distilled water.Sample InjectionUse a 10 mL syringe to slowly inject 1 mL of Kool-Aid solution onto the column.
Discard the effluent that washes out.
Remove the cartridge from the syringe.
Rinse the syringe with 10 mL of distilled water 3 times to erase Kool-Aid residue.Sample ElutionFill the syringe with 18% isopropyl alcohol eluant and attach the syringe to the Sep-Pak Cartridge.
Pump the alcohol through the cartridge with a flow rate of 5-10 mL/min.
Collect effluent in a 10 mL graduated cylinder.
Record volume of effluent collected as first and last of colored drops of each of the dyes exit.If separation is imperfect, record data for the beginning/end of intermediate purple bands. The Center of the purple band acts as the end of the first band and beginning of the last.
Column Regeneration
Repeat measurements two more times. Between injections, wash the column with 10 mL of distilled water at the same flow rate of 5-10 mL/min. If colored residue remains, repeat pretreatment.
Part 2: Step Gradient Separation Now, we change the composition of the eluting liquid. We first use a polar solvent, and then we reduce the polarity of the solid phase by adding isopropyl alcohol.
Through this, we wash out citric acid and flavoring oils in addition. Pretreatment of the Sep-Pak C18 Cartridge Follow the pretreatment in
Part 1. Sample Injection and Component ElutionInject 1 mL of Kool-Aid solution into the column.
Elute polar components of the mixture (citric acid and sugar) bypassing 5 mL of distilled water through the column.
Collect effluent in the first small beaker.
Elute the red dye by passing 10 mL of 5% isopropyl alcohol through the column.
Collect effluent in the second small beaker.
Use 10 mL of the 28% isopropyl alcohol to elute blue dye.
Collect effluent in the third small beaker.
Use 10 mL of 70% isopropyl alcohol to elute nonpolar flavor oils and additives.
Collect effluent in the fourth small beaker.
Record the color of each effluent.Evaporate the solvents and examine the components.Allow the solutions to evaporate and leave them overnight in the fume hood until the next lab period. Label solutions properly.
Observe and describe the contents of each of the beakers. Measure using color, odor, and appearance.Data Table
Part 1: Isocratic SeparationRed Dye
Red Dye
Red Dye
Blue Dye
Blue Dye
Blue DyeRun #1
Run #2
Run #3
Run #1
Run #2
Run #3Start of Band (mL)End of Band (mL)W (mL)V rave (mL)K’Part 2: Step Gradient Separation BeakerEluant
Observations1
H2O2
5% isopropyl alcohol3
28% isopropyl alcohol4
70% isopropyl alcoholCalculations
Determine the following values and show calculations. Refer to question six in the Pre-Lab Questions.
Enter results in the Part 1 data table.Bandwidth W for each dye.
Average Retention Volume V Rave for each dye.
Capacity Factor k’ for each dye.
Selectivity alpha for the two dyes with this isocratic separation.
Resolution R for the two dyes with this isocratic separation.Post-Lab QuestionsWhat is meant by the polarity of molecules? What causes differences in polarity?
In discussing solubility, the rule “like dissolves like” is frequently used. What does this mean?
Draw the structural formula of isopropyl alcohol. Explain how it differs in polarity from water.
For good separation of the dyes, the resolution should be greater than one. What was the value you calculated? Did the two dyes overlap as they emerged from the column, or was the separation a good one?
In the step gradient separation, four separate fractions were collected. How were these related to the polarities of the column and of the eluting solvent?
Approximate price: $22
We value our customers and so we ensure that what we do is 100% original..

With us you are guaranteed of quality work done by our qualified experts.Your information and everything that you do with us is kept completely confidential.You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.The Product ordered is guaranteed to be original. Orders are checked by the most advanced anti-plagiarism software in the market to assure that the Product is 100% original. The Company has a zero tolerance policy for plagiarism.The Free Revision policy is a courtesy service that the Company provides to help ensure Customer’s total satisfaction with the completed Order. To receive free revision the Company requires that the Customer provide the request within fourteen (14) days from the first completion date and within a period of thirty (30) days for dissertations.The Company is committed to protect the privacy of the Customer and it will never resell or share any of Customer’s personal information, including credit card data, with any third party. All the online transactions are processed through the secure and reliable online payment systems.By placing an order with us, you agree to the service we provide. We will endear to do all that it takes to deliver a comprehensive paper as per your requirements. We also count on your cooperation to ensure that we deliver on this mandate.

Never use plagiarized sources. Get Your Original Essay on
Liquid Chromatography Lab
Hire Professionals Just from $11/Page
Order Now Click here